Dec 11, 2017 · HTML code is Off. The DC link voltage is abnormally high. Jun 24, 2014 · I have 5 used RJ3iB controllers that all were supplied by our customer. b. Read on. Fanuc Focas Library CD. Ernesto Perito. In earlier generation Fanuc servo amplifier units; Alarms 8, 9 and A were Abnormal Current alarms. The position deviation value when the n–th axis (axis 1–8) stops is larger than the set value. SFDI is a DCS input B-83525EN/02 MAINTENANCE 3. (Action 1) Check the robot connection cable (RM1) and cables internal to the mechanical section for a short-circuit and connection to the ground. check if is not wiring incorrectly or damaged in switch mode Apr 5, 2021 · I have, in pretty logical order, replaced the 14m RM1 cable, ax2 motor, have a new J1-J6 harness strung along the outside and plugged into the NEW RM1 cable and the new (refurb) 6ax servo amp and each motor / brake connection. Tap the iPendant icon in the lower right corner to open the virtual iPendant keys. Use DMM to check the value of resistor, replace if the value change. . 754 - SPINDLE-1 ABNORMAL TORQUE ALM. We would like to show you a description here but the site won’t allow us. Press COORD until you select the JOINT coordinate system. (EXT) Fanuc Alarm Description A fault occurred in the analog 1VP–P output of the separate detector. Example of inappropriate setting. we are doing every 18 month once we replace the grease . They all feed back to a Fanuc PLC which is then connected to an I/O on the control via IOLINK. Good morning guys! good it's done sometimes when I arrive in the morning to open my Mori seiki SV-500 with Fanuc 18i I have an alarm EX2259 MG-MOTOR IS ABNORMAL after opening it and closing ten times it disappears is this one has an idea of the problem? Thank you for your help Good morning guys! good it's done Apr 20, 2018 · A Fanuc servo amplifier that has an 8, 9, or A alarm indicates high current or short circuit in the amplifier or motor. If the HDD is present but there is still an unformat error, follow steps 3. Cause and troubleshooting. If you want the robot to continue running without having to start it manually every 90 sec, you need to wait for the time variable to drop at 0 each cycle. 266 SRVO-266 FENCE1 status abnormal. 83 SRVO-270 EXEMG1 status abnormal a,b SRVO-271 EXEMG2 status abnormal a,b (Ursache) Es wurde ein Kettenalarm beim EES-Signal (EXEMG) erkannt. Oct 11, 2012 · Control Model. Oct 27, 2014 · Hi all, the machine is Mori Seiki MV40V with Fanuc 0M-C control, 1990year, few days ago we got some kind of vibration on the X axis, the vibrations are with constant period along the whole length of travel, there is no alarm the machine keeps on running but the vibrations from the X axis can be seen on the surface quality. 16/18/21, 16i/18i/21i, 160i/180i/210i, , 0i. Fanuc Alarm SV003 ABNORMAL CURRENT IN SERVO. (Action 3) Replace the panel board. Fanuc 10/11/12/15. 1- SRVO-004 Fence Open 2- SRVO-266 FENCE1 status abnormal Fault will eventually clear after numerous power cycles & attempts to clear alarms to the system. If so, it may be caused by the damage of the cable. droth; March 14, 2017 at 5:17 PM; Thread is marked as Resolved. ① Check whether the LCD screen cable is damaged. droth. (Action 2) Replace the emergency stop board. (Action 1) Check the +24 V connection (between EAS11 and. If there is a 0 on G2A1 you don’t have calibration. Thanks for the support. Any help would be greatly appreciated. TROUBLESHOOTING SRVO-270 EXEMG1 status abnormal SRVO-271 EXEMG2 status abnormal (Explanation) A chain alarm was detected with the EES (EXEMG) signal. With Fanuc alarm 8 on later Fanuc servo amplifier modules the term is now High Current or short circuit in the amplifier or motor. 9156. or. Just like for Elemental Blights, the Wide Range skill can be used for recovery items like the Antidote to cure nearby hunters and buddies afflicted with abnormal status. Set it to "true" and quickly press shift+reset. If a scale-dirt or contamination may be present on sensor or glass. Try Following actions to remove the error: (Action 1): This alarm may be issued when the DEADMAN switch is pressed to a proper position or is operated very slowly. I can read from CR88 @… May 7, 2014 · Re: Fanuc Alarm 438 - Z AXIS : INV ABNORMAL CURRENT. The fuse is not blown, the int 24V & 0V are… Dec 19, 2019 · SRVO-251 DB Relay abnormal. 67. They all are displaying the same 3 faults: SRVO-007 External E-stop, SRVO-213 Fuse Blown (panel board) and SRVO-280 - SVOFF input. JOG-010 Jog pressed before shift. You must determine which axis is at fault before moving on to the next step. SV003 - ABNORMAL CURRENT IN SERVO. Jan 30, 2022 · Im getting Network Status ABNORMAL. Noticed on the panel pcb board that the SVONA (24V) led green light goes off when e-stop is pressed but the SVONB (0V) signals led green light stays on. 2 A cooling fan. If your spindle drive utilizes a liquid-cooled Oct 24, 2018 · I recently purchased a used Fanuc robot, upon wiring it up and clearing the obvious alarms I am stuck with Servo 230 Chain 1 abnormal. The digital servo software detected an abnormality in the motor current detection circuit. Fanuc, Mitsubishi, Yaskawa Fanuc alarm: 363 - n AXIS : ABNORMAL CLOCK (INT) CNC Machine Control Manufacturer. after yesterday we checked the J2 Axis grease contamination level more the 4. The abnormal shaft noise caused by the impact of the motor during the G00 positioning of the machine tool can be eliminated by adjusting 1620, 1621 or 1671, 1672. Confirmation of the connection between TP and panel board-emergency stop-servo amplifier 4. Follow FANUC instructions for powering the controller. 2 3 On the FANUC tablet teach pendant, open the Tablet TPapp. From this value, the percentage to the maximum torque can be obtained by using the following formula: Percentage to the maximum torque = buf. 2 On the side of the FANUC controller, remove the cable entry panel and feed the Ethernet cable through one of the holes. The main circuit capacitor was not recharged within the specified time. F This publication contains proprietary information of FANUC Robotics America, Inc. 08, 8 N/A. 378 FANUC ROBOT ALARM - SFDI22 Status abnormal. Aug 8, 2017 · new to this and could use some help! I have a R J3 controller and an arc mate 120iL, every time we open the fence door or push the e-stop we get SRVO-241 chain 2 (fence) abnormal. 410. Alternatively, abnormal spindle motor load has been detected in Cs mode. This alarm could occur when deadman switch is pressed halfway. 1 Plug the FANUC controller into a power source. We have tried troubleshooting by checking the Estop fuses, TP Switches, TP & controller Jun 17, 2016 · SRVO-248 Deadman switch status abnormal Cause: The status of two DIs of DEADMAN switch do not match. The seven-segment LED on the servo amplifier indicates 1. A chain alarm was detected with the mode switch signal. 378 FANUC ROBOT ALARM - SFDI22 Status abnormal: The K9 and K10 Relays on I/O PCB are not installed. Aug 20, 2018 · I randomly received a SRVO-230 Chain 1 (+24V) Abnormal fault on my RJ3 Controller. JOG-007 Press shift key to jog. since its a new one I am going to have… Jul 5, 2022 · About Press Copyright Contact us Creators Advertise Developers Terms Privacy Policy & Safety How YouTube works Test new features NFL Sunday Ticket Press Copyright Oct 11, 2012 · Additional Suggestions & Alarm Clarification. The technicians at TIE can help repair or replace the cooling fan on your spindle drive. Influence of Noise 2. (quickly because it turns off almost immediately) it is possible you need to restart the controller. Together, we are the strongest Mastercam community on the web with over 56,000 members, and our online store offers a wide selection of training materials for all applications and skill levels. 5 (ah) SRVO-268 SVOFF1 status abnormal a, b / SRVO-269 SVOFF2 status abnormal a, b (87) SRVO-270 EXEMG1 status abnormal a, b SRVO-271 EXEMG2 status abnormal a, b (Explanation) A chain alarm was detected with the EES (EXEMG) signal. Replace them if a defect is found. I have a reference manual for programming, but this refers to MAINTENANC MANUAL B--81465EN if simply releasing and squeezing the dead man's switch doesn't work. With this option, you must jog the robot May 18, 2020 · Be sure to check out our article covering FANUC CNC Troubleshooting Frequently Asked Questions here. SRVO-374 MODE11 status abnormal SRVO-375 MODE12 status abnormal SRVO-376 MODE21 status abnormal SRVO-377 MODE22 status abnormal (Explanation) A chain alarm was detected with the mode switch signal. Whether it’s a replacement servo motor shipped fast, a quality servo repair with a one year warranty, or help with your servo electronics: a faulty drive, a blank HMI monitor, or a scale that no longer repeats or skips count - we’ve got your back. Mar 23, 2013 · On contacting Fanuc India (who then contacted Fanuc Japan), they had asked us to check the following: 1. Feb 20, 2017 · in Fanuc robot J2 axis is abnormal noise was came during movement time. If the robot is not calibrated, perform the following steps: Note For the following steps, press and hold down the SHIFT key until you have completed Step 8a through Step 8d . The abnormal noise is started by the handwheel, and the abnormal noise can be slowed by increasing the 1624 manual time deceleration time constant. 3. SRVO-018 Brake Abnormal. Can anyone please help me with this Oct 11, 2012 · Fanuc alarm: SV003 - ABNORMAL CURRENT IN SERVO. at this stage none of the external safety components are hooked up. If the cooling fan is stopped, check the power supply. its all local. I have a copy of a procedure from a manual for Fanuc 16,18,21 controls to sync the slave to the master. Sponsored Ads. data/32767×100 [%] MTConnect Fanuc Adapter. Hi Guys! An abnormality is detected in internal relay (DB Relay), while using R-2000iC robot with R-30iB controller. 1 Find a Cat5e STP Ethernet cable long enough to reach from the IPC to inside the FANUC controller. Normal Status. Wait for servo power. Check that the signal cables for the fence is not damaged or miswired. Wide Range applies with the most radius at Lv. 06-1999 COMPLIANT R-30 iA Mate CONTROLLER MAINTENANCE MANUAL MARMTCNTR06071E REV. Oct 30, 2019 · (100) SRVO–266 FENCE1 status abnormal. You might try resetting PCA twice and cycling power. The input power supply is abnormal. Originally Posted by hodaken. along with SRVO- 231 chain 2 (0v) abnormal, SRVO-004 fence open, SRVO-199 control stop. 9 Alarm = M Axis. If no alarm appears, there is an issue with the feedback cable or the pulse coder. We also provide repair services for FANUC Power Supplies. Feb 10, 2022 · Alarm is "SFDIxx Status abnormal" A chain alarm was detected with the SFDI signal. Mar 14, 2017 · Fanuc Robot Forum. I have went into the configure screen and tried to reset the Chain failure while in auto and teach mode. c. A. A value from "-32767" to "+32767" is stored. position Feb 18, 2020 · SRVO-374 MODE11 status abnormal Help! Help! The manual says it is about the mode switch or Estop board. a. Jan 27, 2020 · My Fanuc 120iBe RJ3 out of no where started showing some alarms: SRVO-248 Deadman switch abnormal Status. CNC Machine Control Manufacturer. Our team works hard to solve the big problems that come with industrial equipment break downs. There are four sensors- one for each turning spindle and each milling spindle. This code means that one of the robot’s manual movement keys was pressed before the SHIFT key was pressed. Dec 6, 2017 · Also you can check Menu/system/config there is an option, "reset chain failure" or something like that. If SRVO-236 Chain failure is repaired occurred, there is no hardware problem. 10/11/12. Press and continue pressing SHIFT and press F2, RESET. Turn on the main breaker of the machine and leave the CNC off. Total pages: 60960. Input supply voltage imbalance Check the input power supply specification. Plug one end of the Ethernet cable into a LANport on the IPC device (or a network switch connected to the IPC). 04 only . 8 Alarm = L Axis. (Action 2) Check the fence switch. When I look at the Ethernet/IP screen, the status of connection 1 (the PLC) is flashing between online and running…. Confirmation of earth resistance 3. Sep 27, 2018 · I have a R30iB that’s having problems communicating to the PLC. If the deadman is released the second one comes up. Normally, abnormal current is caused by: Bad IGBT, Bad SMD resistor under the IGBT and steel bar (shown in your picture) or small capacitor in the Control board (the board on top of your picture). Go to Setup > Device (side) > HDD (tab). This is the sequence: the first alarm comes every time Deadman is pressed. Even moved network cable from one of the other miners to this one and it still shows abnormal network. Now I have this alarm, and need some advice. Eliminate the cause of Dec 10, 2019 · Bad parenthesis combination. Oct 11, 2012 · Alarm Description. Engineer Tip: make sure it is not a mechanical Jan 26, 2009 · I have a problem with a Fanuc RJ3i S430i system. Replace the emergency stop button on the operator’s panel. 411. Replace the panel board. Simply add this line in your program: DIY-Robotics products Apr 28, 2023 · Abnormal Results. 2. 402 FANUC ROBOT ALARM - SRVO-402 DCS Cart. I have changed the network cable, but I still have the same abnormal status. EAS2) for the fence. Turn the power switch on the FANUC controller clockwise to power the controller on. The input power supply is abnormal (open phase). When it shows running, I’m able to ping it, but when it shows online and… Fanuc 16/ Fanuc 18 CNC Status Display and Details of Diagnostics. 3. Any Idea how to deal with it? Dec 5, 2023 · For spindle motors. I did set the Chain Failure detection to TRUE on the SYSTEM/CONF screen per the fault remedy. 16/18/21, 16i/18i/21i, 160i/180i/210i, , 361 - n AXIS : ABNORMAL PHASE DATA (INT) The input power supply is abnormal (open phase) or the main circuit capacitor was not recharged within the specified time. Mar 15, 2022 · SRVO-377 - MODE22 STATUS ABNORMAL. 378 FANUC ROBOT ALARM - SFDI12 Status abnormal. action 1 - Check the mode switch and its cable; action 2 - Replace the emergency stop board. Fanuc Alarm Description. com. & C. Built 1 zonelists in Zone order, mobility grouping on. I am getting alarm SRVO 230 and 231 saying 24 and 0v chains are abnormal. first try to dismount the coupling between the motor and the axis and run the motor 100% and check if something happend. The offset of the current detection circuit of the main circuit DC link is excessive. If Fanuc servo alarm 8, 9, or A appears when the CNC is off, disconnect the feedback connector to the amplifier axis indicated by the alarm and turn on the main breaker with the CNC off again. Nov 10, 2017 · Like rafahil said the hold signal is not a safety signal and although the PLC e stop will not be the only e stop available, it will be the one most commonly used (it's a testing environment so from time to time the e stop will be necessary) because during normal operation there will be no one standing near the application to press an e stop and the closest person will be the PLC operator Nov 4, 2022 · Hi, I have been dealing with a Fanuc robot R-30iB Plus that started to blow the fuse that goes to the teach pendant dead man. _____ SRVO-374 SERVO MODE11 status abnormal Jul 5, 2022 · About Press Copyright Contact us Creators Advertise Developers Terms Privacy Policy & Safety How YouTube works Test new features NFL Sunday Ticket Press Copyright Mar 9, 2017 · During initial set up and wiring we accidentally miswired the safety board on a R30ib controller and blew the pendant fuse, replaced it and all was well then about 3 days later we have this fault SRVO-375 MODE12 status abnormal Fanuc says it was due to… Abnormal servo motor load has been detected. Sometimes, patients must undergo imaging procedures to diagnose health conditions or injuries. After restarting the controller multiple times it was still present. 16/18/21, 16i/18i/21i, 160i/180i/210i, , 363 - n AXIS Action 2 Replace the axis control card with a card corresponding to the set from ROBÓTICA 3 at Instituto Politecnico National Escuela Superior de Nov 16, 2023 · Robotforum - Support and discussion community for industrial robots and cobots May 16, 2022 · The collaboratives robots from Fanuc need to do this auto status check every 90 sec when the robot is moving continually. Abnormal Status 2) The problem of loosening the cable or wiring port. These procedures include X-rays, CT scans, mammograms, MRIs and more. SRVO-236 Chain failure. Hey all, Replaced the Z2 servo motor and power cable yesterday because we had a burnt cable on the motor end. 5. EXT= External feedback coder used possibly a scale or separate encoder. The bits I need are: Robot Is In Motion Robot In Teach Mode Robot In Auto Mode Robot Is Jogging (by operator). 4. A Alarm = N Axis. SRVO-373 SERVO OPEMG2 status abnormal Cause: A chain alarm was detected with the emergency stop switch on the operator’s panel. Go to master cal and single axis master. Step 1. Oct 11, 2012 · Any additional suggestions or recommendations on the Fanuc alarm: SV003 - ABNORMAL CURRENT IN SERVO message please post comments below. so better try a new motor . If the control does not issue an alarm, press the DGNOS button to display the contents of the following diagnostics: Display of status when a command is not apparently executed (DGN No. READY Hardware. December 19, 2019. Jul 16, 2021 · It was fine when I first turned it on. Remember to discharge the capacitor before you test. The K9 and K10 Relays on I/O PCB are not installed. Remedy: 1. Control Model. Normally the standard 8, 9, A alarms will appear with an alarm on Jun 11, 2014 · What control do you have? I looked through the Fanuc 16,18,21 manuals I have and the parameter 3015 is not listed, jumps from 3011 to 3017. Feb 4, 2019 · Alarm Search Results: 9156. Conversely, do subsequent investigations. In such a case, release the DEADMAN switch once completely then press the DEADMAN switch FANUC Robot series RIA R15. (Maßnahme 1) Prüfen Sie, ob die Schaltung zum Binär-Eingangssignal (EES) fehlerhaft ist. SERVO ALARM: n–TH AXIS – EXCESS ERROR. Diagnosis of alarm codes on the CNC machine can be an expensive time waster. What would cause this alarm? View More. TBOP20 connector and cables in the Fanuc Control Box or the Interface Box M12 connector Robot Signals. i had one month ago this with huge vibration of the motor when it stand still. PSMR Apr 27, 2023 · I’ve got a FANUC Robot M-10iA, every morning during power up I get 2 alarms. Safety Hardware. (Action 1) Check whether the circuitry connected to the dual input signal (EES) is faulty. SERVO ALARM: n–TH AXIS – EXCESS ERROR Nov 28, 2019 · For "SRVO-275 NTED2 status abnormal" error: a chain alarm was detected with the NTED signal. For "SRVO-275 NTED2 status abnormal" error: a chain alarm was detected with the NTED signal. Mode selector switch may be faulty. to 5. The specification of the AC reactor does not match the PSM in use. I can try to send it to you if you are interested. Otherwise, replace the cooling fan. NOTE. There’s a list of Fanuc Alarm codes below to help. 378 FANUC ROBOT ALARM - SFDI12 Status abnormal or 9150. Refer to the Robot Installation Procedure, Electrical section. Didn't find what you were looking for? I’ve got a FANUC Robot M-10iA Feb 13, 2015 · Join us! eMastercam - your online source for all things Mastercam. R-30iB or R-30iB Plus (style A cabinet) No DCS option, no additional hardware - integrates the READY pendant Emergency Stop to the standard robot safety I/O, but not the Key Switch or Enabling Switch. (Action 1) Check the mode switch and its cable. Make sure you have the K9 and K10 relays installed on the I/O PCB. Updated on May 18, 2020 by Brian Hughes Apr 27, 2024 · Diagnosis and Correction of Fanuc Alarm Codes. Are variables that represent these statuses somewhere on the controller? Apr 16, 2023 · Refer to the table before this section for the cure to every abnormal status effect! Have Wide Range for Curing Abnormal Status. It was working at the beginning, but suddenly started to blow that fuse, we tried replacing the pendant with one that was already working and all pointed out that the dead man of the teach pendant could be damaged Fanuc 8, 9, A, b, C, D, HC: High Current Alarm. Aug 30, 2023 · 9156. A06B-6087-H130 alarm codes. pcpu-alloc: [0] 0 [0] 1. Aug 30, 2021 · This FANUC Alarm code list covers: 0i Model A, 0i/0iMate Model B, 16/18 Model PB, 16/18 Model C, 16i/18i Model A, & many more FANUC fault codes. I have replaced the power wires, network cable, router and can verify I have a stable connection as I have 3 goldshell mini working on the same network. Control supply voltage decrease of the power module (IPM) Replace the power unit. The status of the CNC can be monitored at all times. 000 – 015) 000: WATING FOR FIN SIGNAL We would like to show you a description here but the site won’t allow us. Fanuc. If the HDD is blank, continue the steps in No hard drive or hard disk found. Excessive current was detected in the velocity control circuit. No other uses are authorized without the express written permission of FANUC Robotics America, Inc. Universal Fanuc Driver. 4 In the main circuit the DC voltage (DC link) has dropped. the alarm of the DCS Cartesian position check occurs, and the servo power of the robot is cut off, the system becomes safety state. MACR-013 MACRO execution failed. 07, 7 N/A. check servo motor ,Fanuc controller parameters, Parameters settings,Fanuc controller Plug the power adapter of your DVR or NVR directly to a known working outlet. Jun 30, 2015 · Looking in the electrical manual, I see that there is something called “Spindle speed monitoring detection”, also referred to as “Spindle monitor”. What the hell? I don't see anything broken or burned. Fanuc 0i/0i Mate Fanuc 10/11/12 Fanuc Series 15 Fanuc 15i Fanuc 16i 18i Fanuc 21 Fanuc 21i Fanuc Alarms Fanuc Spindle Alarms Fanuc 6M 6T Alarms Fanuc Alarm 646 n AXIS: ABNORMAL ANALOG SIG. Alarm Description. does this mean that the 0v circuit is not breaking? also the KA1-KA3 relays on the redundant unit Fanuc Alarms Fanuc 0i/0i Mate Fanuc 10/11/12 Fanuc Series 15 Fanuc 15i Fanuc 16i 18i Fanuc 21 Fanuc 21i Fanuc Alarms Fanuc Spindle Alarms Fanuc 6M 6T Alarms Fanuc Alarm SV330 ABNORMAL COMMUNICATION (SPLC) FANUC PMC STATUS CHECK Sep 11, 2014 · I need to copy some status bits out to Ethernet/IP so my other system has a picture of what the robot is doing (for diagnostic purposes). 06, 6 N/A. Step 4. After recycling power once again it seems to be working fine. FEHLERBEHEBUNG WARTUNG B-82725GE-1/01 3. Jan 21, 2020 · Hi Guys. Replace the teach pendant cable. Kernel command line: mem=240M console=ttyPS0,115200 ramdisk_size=33554432 root=/dev/ram rw earlyprintk. The alarm points to the axis in question. 5 a. i also set… Dec 23, 2021 · Re: SV0441 ABNORMAL CURRENT OFSET FANUC 32I. ② Please reintegrate the cable port ends to eliminate the problem of loose wiring or the wiring is not in place. 8. 7 DC link is abnormally high. Reactions Received 11 Dec 10, 2019 · Hi Frankie! As per manual if Servo 0-18 An excessive brake current is detected. Forum Rules. Speeds are limited by Forge/OS instead of by safety-rated hardware. Dealing with alarm codes is a matter of first understanding what they mean, and then deciding what’s causing the code based on the code’s meaning. xx shows the signal name. Wait for the controller to boot up. 5 month before we checked grease metal contamination level was 0. CNC diagnostic 1723 reports the RPM reading of the fan, diagnostic 1724 is for the amplifiers that have two internal fans. SRVO–267 FENCE2 status abnormal (Explanation) The fence circuit is abnormal. 1 (for PSM-22i to 55i) Over current flowed into the input of the main circuit. below. Thanks!!!!! BOOK SAYS: The current offset value of the current detector (equivalent. A chain alarm was detected with the EAS (FENCE) signal. Jan 5, 2024 · About Press Copyright Contact us Creators Advertise Developers Terms Privacy Policy & Safety How YouTube works Test new features NFL Sunday Ticket Press Copyright Meaning The main circuit power module (IPM) has detected an abnormal condition. Wait for the tablet to connect. The robot’s manual movement key was pressed but the SHIFT key was not pressed. Cleaning can sometimes fix the problem. after we plan to replace the fanuc manipulator unit. Apr 5, 2023 · check servo motor status, Basic parameters Fanuc controller,Tamp. In such a case, release the DEADMAN switch once completely then press the DEADMAN switch EGS1 EGS11 EGS2 EGS21 Fig. Mar 9, 2017 · So I have my first brand new robot, I am looking for the paremeter to reset the fault when you hold the deadman switch. If NSI[1] becomes ON when the robot is on P[2] in the above figure, zone 2 becomes enabled and. this is a type A cabinet. -. Release both deadman switches at once. 267 SRVO-267 FENCE2 status abnormal. On the FANUC tablet teach pendant, open the Tablet TP app. May 7, 2012 · 4. EAS1) and 0 V connection (between EAS21 and. A chain alarm was detected with the SFDI signal. furnished for customer use only. I took it for granted my other robots were configured already with usefull options turned on. If a Fanuc Alarm 01 Code is issued during cutting: (a) Investigate the cooling state of the spindle motor. Follow. If a patient has abnormal results from these procedures, they must be told about it immediately so that the condition can be treated in time to avoid causing Feb 14, 2014 · Hi guys, I have a device i want to stop by sending a DO under differents conditions, like when a collision occur, an e-stop is pressed or a DCS fault is detected I been able to send an output when a e-stop is pressed in menu-->system-->config. SAFE I/O. B-83184EN/04. Blue meter for capacitor. action 3 - Replace the main board. 6 The control power supply voltage decreases. Alpha-iB series of amplifiers (A06B-62xx-Hxxx) also have a diagnostic that shows you the fan speed on your Fanuc CNC. 5. Replace the teach pendant. 9150. For more information or to get a quote on a FANUC power supply, please call 800-691-8511 or email sales@mroelectric. iy vh au wx jh fs es cw bi zc